LUBRIFICANTES DOW CORNING® 4 ELECTRICAL INSULATING COMPOUND

O Composto Isolante Elétrico Dow Corning® 4 pode ser aplicado à mão, equipamento automatizado especialmente projetado, escovação ou limpeza. Certos modelos de pistolas de graxa podem aproveitar os compostos de silicone; teste antes do uso.

 

United States Regulations -> FDA (Food and Drug Administration) -> 21 CFR 175.300
United States Regulations -> National Sanitation Foundation Standard 51
United States Regulations -> National Sanitation Foundation Standard 61
Europe Regulations -> WEEE/ROHS Compatible
Appearance -> Oil Bleeding
Resistance -> Chemical Resistance
Resistance -> Oxidation Resistance
Resistance -> Ozone Resistance
Resistance -> Solvent Resistance
Resistance -> Water Resistance

 

Arc Resistance= 135
ColorTranslucent
ColorWhite
Dielectric Constant at 100 Hz= 2.98
Dielectric Constant at 100 kHz= 3.01
Dielectric Strength> 460 volts per mil v/mil
Dissipation Factor at 100 Hz= 0.0001
Dissipation Factor at 100 kHz< 0.0002
NLGI Number= 2
Oil Resistance
Service Temperature High= 200 Deg C
Service Temperature Low= -40 Deg C
Shelf Life= 1800 Days
Specific Gravity @ 25C= 1
Volume Resistivity= 1.1e+015 ohm-centimeters
Water Resistant
Worked Penetration= 310 mm/10